Shop By Category
Help & Settings
- Customer Service
- Sign in / Sign up
Start by mapping the space the Integra 4" wall system will define: overall footprint, wall heights, and how traffic will flow through doors and corners. A modular wall system is most successful when you plan panel runs around fixed obstacles (columns, sprinklers, electrical drops, conveyors) and identify where you need openings for personnel doors, pass-throughs, or windows. Confirm what “4-inch” refers to for the specific system configuration you’re purchasing (e.g., overall wall thickness or panel profile) and verify how that thickness affects usable interior square footage, jamb details, and interface to existing door hardware.
Next, choose the configuration based on the environment and the job the partition must do. For warehouse offices or assembly support areas, you may prioritize a clean finished surface and the ability to route power/data cleanly; for tool cribs or high-traffic aisles, impact resistance and repairability become more important. If temperature control, noise reduction, privacy, or dust control matters, compare panel construction options and gasketing/seal approaches as specified by the manufacturer—performance varies by panel type, joint design, and how well the system is installed.
A frequently overlooked check is how the wall system ties into the building and surrounding systems. Verify acceptable anchoring methods for your floor type (slab thickness/condition, coatings, joints) and how the top of wall is stabilized (to structure, to ceiling, or via bracing) per the manufacturer’s requirements. Also confirm what you’ll do at the perimeter: sealing to existing walls, dealing with uneven floors, accommodating expansion joints, and maintaining required clearances around sprinklers, electrical panels, and egress routes. These details often drive which posts, trim, and accessory kits you actually need to order.
A1: It’s used to create interior partition walls—such as offices, tool cribs, inspection rooms, and separated work zones—using modular panels and posts rather than traditional framed construction. The value is reconfigurability and speed of layout changes, especially when operations evolve.
A2: Not always. “4-inch” may refer to a nominal system thickness, panel profile, or family name depending on the manufacturer’s definition. Verify the actual assembled thickness (panel plus post/trim) on the product data sheet because it affects door jamb detailing, trim interfaces, and space planning.
A3: Choose height based on what the space needs to accomplish—visual separation, security, dust control, or acoustics. Full-height walls (to structure) can provide stronger separation but require coordination with sprinklers, lights, and overhead utilities. Partial-height walls may be easier to install but often need a defined top stabilization method and may not deliver the same containment. Confirm the manufacturer’s guidance for top-of-wall attachment and any height limits.
A4: Many modular wall systems support door frames, glazing panels/windows, and pass-throughs, but the available sizes and framing details vary by system. Plan openings early so you can order the correct frame kits/posts and avoid field modifications that may reduce strength or finish quality. Confirm door swing/handing, hardware compatibility, and any required reinforcement for high-traffic doors.
A5: Confirm how the system is designed to be anchored to your floor type (bare concrete, coated slab, existing tile, expansion joints) and how it is braced or attached at the top. Also check tolerances for floor flatness and plumb—uneven slabs may require shimming, leveling trim, or specific base details. For compliance and safety, coordinate installation requirements with the manufacturer’s instructions and your facility constraints (sprinklers, egress, and clearances).
A6: Performance depends on the specific panel construction and joint/seal design. Some configurations may offer better acoustic or thermal behavior than others, but it isn’t automatic. If sound reduction or temperature control is a goal, request the manufacturer’s performance data (e.g., acoustic ratings where available) and plan for sealing at joints and perimeters.
A7: Start with a scaled layout showing each wall run length, corners, intersections, and every opening. From there, determine panel counts by module width, then add the correct posts/connectors for corners and tees, plus base/top trim and any seal or stabilization components. Include extras for field conditions (end caps, fillers, transitions to existing walls). If you have a drawing, share it with Janeice Products Co Inc so you can confirm you’re not missing less-obvious items like jamb kits, corner posts, or termination hardware.
A8: Use cleaning methods that match the panel facing and finish listed by the manufacturer. In many industrial environments, avoiding overly aggressive abrasives helps preserve appearance and cleanability. If the space will be sanitized frequently or exposed to oils/chemicals, verify chemical compatibility and inspect joints/trim periodically so small impacts or gaps don’t turn into ongoing dust or debris traps.