Shop By Category
Help & Settings
- Customer Service
- Sign in / Sign up
Shop industrial replacement spray head for eyewash units at Janeice Products Co Inc. A worn, clogged, or damaged spray head can reduce flow quality and coverage, making it harder for an eyewash station to deliver a consistent, comfortable rinse when seconds matter. Replacement spray heads help keep plumbed and self-contained eyewash units performing to the manufacturer’s intended spray pattern, helping maintain readiness in production areas, labs, maintenance shops, and other workplaces where airborne debris or chemical splashes are possible. Janeice Products Co Inc in Aiken, South Carolina supplies industrial safety equipment parts so you can restore function without replacing the entire eyewash assembly when a spray head is the only component that needs attention.
Sort By
Start by matching the spray head to the exact eyewash unit brand and model (and, when available, the unit’s part number). Eyewash spray heads vary widely in how they attach—thread type and size, push-in or bayonet-style fittings, integrated check/flow components, and whether the head is left/right specific. If you’re replacing only one side on a dual-head eyewash, confirm whether the heads are sold individually or as a pair and whether the spray pattern and height will match the remaining side to provide even coverage.
Next, consider the use environment and why the spray head is being replaced. In dirty or dusty areas, prioritize designs that are easier to clean and less prone to clogging, and confirm the compatibility of any built-in strainers or screens. In chemical handling areas, verify the spray head materials and seals against the chemicals present and the water temperature range expected at the station. Also confirm that the replacement maintains the intended “aerated” or “non-aerated” flow behavior for user comfort and effective flushing—this can be model-dependent and should be confirmed against manufacturer data.
A frequently overlooked check is activation and protection hardware compatibility. Some eyewash units use flip-top dust covers or automatic-opening caps linked to the activation paddle; others rely on separate protective caps or shields. Make sure the replacement spray head accepts the correct cover/actuation method so the station can be kept clean and still activate instantly. After installation, test the unit per the eyewash manufacturer’s instructions to confirm symmetrical spray, stable flow, and proper alignment before returning it to service. (Confirm any compliance or performance requirements with your safety program and the eyewash unit documentation.)
A1: Use the eyewash unit’s manufacturer and model number first, then match the spray head part number if available. Fit depends on the connection method (thread type/size or proprietary coupling), sealing style (O-ring seat, gasket face, tapered threads), and whether the head is left/right specific. If you can’t identify the part number, compare detailed photos/drawings and measure the connection interface, but confirm final compatibility against the eyewash manufacturer’s documentation.
A2: Usually not. Even when they look similar, spray heads can differ in attachment geometry, internal flow formation, and dust cover/activation interface. Using a “close match” can cause leaks, incorrect spray pattern, or misalignment. For safety equipment, it’s best to source a manufacturer-matched replacement or a specifically cross-referenced compatible part and verify it against the unit’s specifications.
A3: If only one is damaged you may be able to replace a single head, but replacing both can help keep spray pattern, height, and outlet condition consistent on dual-head units. If the remaining head shows discoloration, cracking, clogged outlets, or a different spray behavior during testing, replacing as a pair may reduce troubleshooting and help maintain symmetrical coverage.
A4: Aerated designs mix air to create a softer, more comfortable flow that can reduce splash-back, while non-aerated designs rely on outlet geometry to form streams/spray without added air. The “right” choice is the one specified for your eyewash unit because the station’s performance is designed around that outlet behavior. When ordering, verify the manufacturer’s spray head type rather than switching styles.
A5: Not always, but it’s a common reason to replace. First check for debris in the head, any screen/strainer, and the water supply line (following the eyewash manufacturer’s instructions and your facility procedures). If outlets are eroded, cracked, permanently blocked, or the spray pattern remains uneven after cleaning and flushing, replacement is typically the practical fix. Also confirm that protective caps are present and functioning to prevent recurring contamination.
A6: It depends on the model. Some spray heads include integrated caps; others require separate covers or use a cap linked to the activation mechanism. Before ordering, confirm whether caps are included, whether existing caps can be reused, and whether the cap style is compatible with your activation paddle and head design so the unit stays clean without slowing activation.
A7: Installation complexity varies by unit and connection type. Follow the eyewash manufacturer’s instructions and your facility maintenance/safety procedures. After installation, activate the eyewash and verify: no leaks at the connection, stable flow, symmetrical spray from both heads (if applicable), and proper alignment at the intended eye level. Also confirm dust covers open as intended and that the station is returned to its normal ready state.
A8: Provide the eyewash unit manufacturer, model number, and any part number from the unit manual or the existing spray head. Helpful extras include photos of the current spray head and connection point, whether it’s plumbed or self-contained, and whether you need left/right/both heads and dust covers. If you’re unsure, ask Janeice Products Co Inc in Aiken, South Carolina to help you verify the correct part based on the unit identification information you have.