Shop By Category
Help & Settings
- Customer Service
- Sign in / Sign up
Shop industrial urethane hose & cable crossovers at Janeice Products Co Inc for safer, more organized temporary routing where hoses and cords need to cross walkways, door thresholds, and light vehicle paths. These protect hose and cable jackets from abrasion and pinch points while helping reduce trip hazards in plants, maintenance bays, event setups, and outdoor work zones. From Aiken, South Carolina, Janeice Products Co Inc supplies crossover solutions suited to crews who need fast placement and reliable protection around pedestrian traffic, carts, and equipment moves—without permanently modifying the floor.
Sort By
Start by matching the crossover to what you’re protecting and how it will be used. Confirm the number of channels you need (single vs. multi-channel), then verify each channel’s usable width/height against the largest connector, coupler, or strain-relief on the line—not just the hose or cable OD. If you’re running air lines with fittings, power cords with molded plugs, or data cables with oversized ends, you may need a larger channel or a design that allows easier drop-in loading. Also consider the route length: some crossovers are modular and connect end-to-end, while others are individual sections intended for short crossings.
Next, choose a configuration that fits your traffic and environment. For mostly foot traffic and hand trucks, prioritize a low profile with beveled edges that helps wheels roll over smoothly. If carts, pallet jacks, or vehicles may cross, confirm the manufacturer’s load rating and intended traffic class before you buy; urethane compounds and internal reinforcement can vary widely by model. For wet areas, washdown zones, or outdoor use, check for tread texture and the ability to shed water and debris so the crossover doesn’t become slick or unstable.
A frequently overlooked check is floor interaction and placement control. Confirm whether the crossover’s base is designed to stay put on smooth concrete, coated floors, asphalt, or temporary surfaces (mats, plywood, grass). If you’ll reposition it often, look for designs that are easy to carry and deploy without twisting or curling, and verify how sections connect so you don’t end up with gaps that catch wheels or expose lines at the seams.
A1: Urethane crossovers are often selected for high abrasion resistance and durability where repeated crossings and dragging occur. Rubber may offer good grip and flexibility, while PVC options can be cost-focused and lighter-duty depending on the design. The right choice depends on traffic load, exposure (oils, UV, weather), and how often the crossover will be moved—always confirm the manufacturer’s material and use-case guidance.
A2: Measure the largest part that must pass through the channel: hose/cable outer diameter plus any thick jackets, strain reliefs, couplers, or molded plugs that will sit inside the channel. Compare those measurements to the channel’s usable width and height (not just a nominal size). If connectors can’t fit, consider a larger channel, a different channel shape, or a design that allows placement where connectors sit outside the channel when feasible and safe.
A3: Some models are designed for heavier traffic, but it’s not universal. Check the published load rating and the stated traffic type (pedestrian, light vehicle, industrial vehicle) on the manufacturer’s data sheet. Also verify whether the rating is per axle, per wheel, or distributed, and consider wheel type (hard caster vs. pneumatic) because small hard wheels can concentrate loads and damage a crossover or the lines underneath.
A4: They can be, but you should verify the specific model’s temperature range, UV resistance, and slip characteristics when wet. Look for tread patterns and drainage features if the crossover will sit in rain or washdown areas. For outdoor deployments, also confirm how the crossover stays positioned on asphalt, concrete, or uneven surfaces.
A5: Choose based on how frequently you’ll change lines and how quickly you need setup. Lidded/drop-in designs can speed installs when you’re laying multiple cables or reconfiguring often, but you’ll want to confirm the lid’s closure security and hinge durability for your traffic. Solid drop-over styles can be simpler for single hoses/cords and quick placements where feeding a line through isn’t a burden.
A6: Select a model with an appropriate base design for your floor type and a low, beveled edge. Keep the surface under it clean (dust and overspray can reduce friction), and avoid placing it over oil films or loose debris. If modular sections are used, confirm the connection method prevents separation that can form a gap. For critical pathways, consider additional placement controls only if allowed by the site (and compatible with the crossover design).
A7: They primarily provide mechanical protection from crush and abrasion. They won’t inherently prevent electromagnetic interference; if you’re running sensitive data lines, manage separation from power lines per your site standards and cable manufacturer guidance. Also verify the channel size and bend path so cables aren’t forced into tight bends that can degrade performance.
A8: Remove grit and debris regularly because embedded sand/metal fines can increase wear and create slick spots. Clean with methods compatible with the manufacturer’s recommendations for the urethane compound—some solvents or aggressive chemicals may cause swelling or surface degradation. Inspect for deformation, cracking, damaged edges, or channel wear that could expose lines or create a trip point, and replace units that no longer sit flat or protect the lines adequately.
A9: Many crossover systems are modular, but connection styles vary. Confirm whether the model supports end-to-end linking, what hardware (if any) is required, and whether connected sections remain flush under load. If you need turns, verify whether matching corner pieces or directional transitions exist rather than forcing a bend that pinches the lines.
A10: Share the number and type of lines (hose, power, data), the largest connector dimensions, the expected traffic (foot, carts, pallet jacks, vehicles), indoor/outdoor exposure, and the length of the crossing area. If you have floor type details (smooth concrete, epoxy-coated, asphalt) and any safety requirements for visibility, include those as well so the recommended options align with your site conditions.