Start by matching the frame to the racking system you’re working with. “Unirak” can refer to a specific rack family, and frame geometry (upright profile, hole pattern/pitch, and beam-connector interface requirements) must align with your beams and accessories. Before ordering, confirm the manufacturer/series identification from existing uprights or documentation, and verify that replacement frames are intended to interchange with your current beams, row spacers, cross bracing, and pallet supports. Mixing non-matching patterns can create fit issues and may compromise intended performance.
Next, size the frame around both storage needs and building constraints. Frame height, depth, and upright gauge/section are primary drivers of capacity and stability, and they should be selected based on the maximum pallet weights, beam elevations, and the number of load levels you plan to use. Consider clearances for sprinklers, lights, ductwork, and lift-truck mast height; also account for required aisle widths, rack-to-wall clearances, and the slab condition where anchors will be installed. If your rack will be tall, heavily loaded, or exposed to higher impact risk, pay extra attention to frame bracing configuration and the manufacturer’s allowable load tables.
A frequently overlooked check is floor and installation compatibility. Frame capacity assumes specific anchoring, plumbness, and shimming limits; uneven slabs or missing anchors can reduce performance. Confirm required anchor type/quantity, base plate style, and allowable shim thickness per the manufacturer’s instructions. Also verify any environmental or operational factors—such as cold storage temperatures, corrosive washdown areas, or high-traffic lift zones—that may warrant specific finishes, guards, or heavier-duty frame construction.
A1: A Unirak frame is the vertical upright assembly (two uprights with bracing and base plates) that forms the sides of a racking bay. Beams span between two frames and carry the pallet loads. Frames primarily determine bay height, depth, and much of the system’s stability and capacity; beams determine the load level spacing and per-level capacity based on their rating and span.
A2: Confirm the upright series/profile and the hole pattern/pitch that your beams connect to, then match the frame depth and height to your existing layout. If you can, reference the manufacturer label or part identifiers on the uprights, and compare connector engagement (number/shape of tabs or hooks) required by your beams. When details are uncertain, measure the upright face width, perforation spacing, and frame depth, and verify interchangeability against manufacturer documentation before ordering.
A3: Choose depth based on your pallet footprint and overhang policy (how much pallet can extend beyond beams), then choose height based on the number of pallet levels, required clearances, and your lift’s maximum lift height at the needed load. Also account for sprinkler/lighting/ductwork clearance and any facility requirements for flue space between back-to-back rows. Final dimensions should be verified against your rack layout drawing and the manufacturer’s application limits.
A4: Frame capacity is typically provided in manufacturer load tables and depends on multiple variables: upright size/gauge, bracing pattern, frame height and depth, beam elevation spacing, and installation conditions (anchoring, shimming, and plumbness). For a safe selection, size the frame using the exact configuration you plan to build—don’t rely on a single “maximum” number without confirming the matching table for your beam spacing and intended loading.
A5: Sometimes mixing components is physically possible, but it’s not automatically compatible or advisable. Differences in hole patterns, connector geometry, and design assumptions can affect fit and rated performance. For safety and compliance with manufacturer intent, verify compatibility and allowable ratings with the component manufacturers (or a qualified rack professional) before combining different brands or series.
A6: Frame installation typically requires anchoring base plates to a sound concrete slab using anchor type/size specified by the rack manufacturer. The slab must support the imposed loads, and the rack must be installed plumb with shims kept within manufacturer limits. If your floor is cracked, uneven, or has questionable thickness/strength, evaluate the slab and confirm the anchoring approach before installation to avoid reduced performance.
A7: That depends on your layout and height-to-depth ratio. Back-to-back rows commonly use row spacers to maintain consistent flue space and add stability; single rows may use wall ties where required by design. Whether they’re required (and at what spacing) is configuration-specific, so confirm against the rack design guidance for your frame height, loading, and any seismic or local requirements.
A8: Use impact protection where trucks regularly travel—such as upright/column guards and end-of-aisle barriers—selected to fit the upright profile and base area. Inspect frames routinely for bent uprights, damaged bracing, missing anchors, or excessive corrosion, and address impacts promptly; a frame that’s out of plumb or visibly deformed should be evaluated before continuing service. Replacement should follow manufacturer guidance so the repaired bay returns to a spec-appropriate configuration.
A9: Provide the required frame height and depth, upright series/profile (or clear photos of the upright face and beam connection), the number of frames needed, and your intended use (pallet weights, number of levels, and beam elevations). If you’re matching existing rack, include details on the current beams and any accessories (row spacers, guards) you need to remain compatible with. If you’re unsure, share measurements and photos so the correct configuration can be confirmed before ordering.