Shop By Category
Help & Settings
- Customer Service
- Sign in / Sign up
Shop Add-A-Level Work Platform Components at Janeice Products Co Inc in Aiken, South Carolina. These components let you build, expand, or reconfigure modular work platforms used in standing work areas to improve footing, reduce fatigue, and adapt a station to changing processes. Buyers use them to replace worn sections, extend a platform run along a bench or line, add transitions at entry points, and customize layouts around equipment bases, carts, or operator reach zones. They’re a practical fit for maintenance teams, production supervisors, EHS professionals, and facilities staff who need flexible platform coverage without reworking an entire workstation footprint.
Sort By
Start by defining what you’re trying to change in the platform: add length, create an L-shape, replace a damaged section, improve entry/exit, or bridge a gap between adjacent standing areas. Measure the usable standing footprint (not just the space available) and note any obstructions such as machine legs, posts, or guardrails. With modular platforms, the “right” component is often determined by how it interfaces with what you already have—confirm the platform series/family, section dimensions, edge/transition style, and connection method so new parts mate correctly with existing units.
Match the component to the work environment and traffic. In dry assembly areas you may prioritize comfort and stable footing, while in machining, washdown, or areas with coolants you’ll want components intended to manage liquids and maintain traction when wet. Also consider whether carts, pallet jacks, or frequent foot pivots occur at the station; that can influence which edge pieces, ramps, and surface patterns make sense and how robust the connectors need to be. If your site has ESD requirements, treat that as a specification to verify on the exact component rather than an assumption.
A frequently overlooked check is elevation and transition planning. Even small changes in platform height can affect door clearances, toe-space at benches, and the way operators step on/off the platform. Before ordering, map where beveled edges/ramps are needed versus where straight edges can remain, and confirm whether local safety practices call for high-visibility borders or specific edge profiles. If you’re replacing only a section, verify whether older and newer revisions of the platform system use the same locking geometry and whether a transition piece is required to keep the surface continuous.
A1: It generally refers to the modular parts used to build or modify a work platform system—such as center sections, edge/border pieces, corner pieces, entry ramps/bevels, connectors, and related hardware. The exact component set depends on the platform system design, so it’s important to match the component type to the function you need (expand, transition, replace, or connect).
A2: Confirm the platform system/family name, the section size (length/width), and the connection style used on your current platform (for example, the shape of interlocking tabs or clips). If your platform is older, verify whether there have been design revisions that change the lock geometry. When in doubt, compare part numbers or provide photos and measurements to Janeice Products Co Inc so you can confirm compatibility before ordering.
A3: Perimeter risk is usually addressed with edge/border pieces and entry transitions (beveled edges or ramps). Use straight borders along open sides, corners at turns, and ramps where operators commonly step on/off or where rolling items approach the platform. Confirm the ramp/edge profile is intended for your traffic type (foot-only vs. carts) and that the finished perimeter stays flush and continuous.
A4: Some modular platform components are designed to manage liquids and maintain traction, but suitability is model- and material-dependent. Verify the component’s material, surface design, and the manufacturer’s stated chemical and temperature compatibility for your specific fluids and cleaning agents. If washdown is involved, also confirm whether the design is intended for frequent high-pressure cleaning and how it should be dried or reassembled afterward.
A5: Often, yes—expansions may require specific connector pieces or locking hardware to secure new sections to existing ones, plus additional edges/corners to finish the new perimeter. Plan the final footprint first, then list how many interior joints and perimeter sides you’ll create, and select connectors and border pieces accordingly. Check whether the system uses tool-free locking or requires separate fasteners.
A6: Focus on transitions designed for rolling loads—typically ramps or low-profile beveled edges—then confirm the manufacturer’s guidance on allowable loads, wheel types (hard vs. soft), and approach direction. Also consider traffic frequency: repeated crossings concentrate wear at the entry, so selecting a robust transition piece and keeping a spare can minimize downtime. If pallet jacks or heavy rolling loads are involved, verify suitability explicitly rather than assuming standard edge pieces will hold up.
A7: Identify whether the damaged area is a center section, edge, or connector point, then confirm the system’s disassembly sequence (some designs require removing a border to release adjacent sections). Match the replacement piece by size and connection type, and inspect neighboring connectors for wear so the new section locks securely. After replacement, verify the surface is level and the perimeter transitions remain flush.
A8: Usually not. Interlocking geometries, heights, and edge profiles vary by manufacturer and product family, and mixing systems can create gaps, uneven transitions, or weak connections. If you’re trying to interface two different standing surfaces, look for purpose-made transition solutions and confirm heights and attachment methods with the manufacturer specifications before buying.