Shop By Category
Help & Settings
- Customer Service
- Sign in / Sign up
Shop industrial EPDM (200 Series) Goat Throat Pumps at Janeice Products Co Inc. Designed for drum and tote fluid transfer, these pumps use EPDM elastomers to support dependable priming and dispensing on compatible liquids in production, maintenance, and material-handling workflows. Common applications include moving water-based chemicals, mild cleaners, and other EPDM-compatible fluids from 55-gallon drums to day tanks, parts washers, or fill stations—where a simple, air-free suction lift and controlled discharge help reduce spills and wasted product. Janeice Products Co Inc in Aiken, South Carolina supports facilities that need practical pump selection guidance for routine dispensing, batch make-up, and line-side replenishment.
Sort By
Start with fluid compatibility and concentration—not just the fluid name. EPDM is often selected for water-based solutions and many cleaners, but it can be incompatible with petroleum oils, fuels, and many hydrocarbon solvents. Verify the full wetted-materials list (not only the seal) and confirm compatibility against the chemical SDS and the pump manufacturer’s chemical-resistance guidance, especially if your fluid is heated, highly concentrated, or blended with additives.
Size the pump around how you actually dispense: intermittent small fills vs. continuous transfer. Compare required flow rate, achievable suction lift, and viscosity range at your expected temperature. Also check discharge style and end-use: a hose and nozzle for container filling, a hard-piped outlet for a fixed station, or a valve-controlled outlet for batching. If you need repeatable fills, look for configurations that accept metering accessories or that maintain consistent prime/flow when the drum level drops.
A frequently overlooked check is drum and bung fit plus grounding/bonding requirements for your process. Confirm the bung thread size and whether you need a rigid suction tube length matched to your drum/tote depth. If there’s any chance the fluid or environment requires static control, confirm whether a conductive discharge hose, bonding strap, or specific pump construction is required per your facility safety rules—don’t assume any pump configuration provides static protection without manufacturer confirmation.
A1: It generally indicates a Goat Throat Pump configuration built with EPDM elastomer components as part of a specific series/variant. EPDM selection is mainly about chemical compatibility and seal performance. Confirm with the product listing or manufacturer datasheet which components are EPDM and what other wetted materials are used, since overall compatibility depends on the entire wetted path.
A2: Choose EPDM when your fluids are typically water-based and EPDM-compatible (often many cleaners and certain aqueous solutions). Avoid EPDM for many petroleum oils, fuels, and hydrocarbon solvents. If your application involves mixed chemistry, elevated temperature, or high concentration, validate compatibility using the SDS and the pump manufacturer’s chemical resistance guidance rather than relying on general rules.
A3: Often not, depending on the solvent or oil. EPDM can degrade or swell in many hydrocarbon-based products, which can cause leaks, loss of prime, or shortened seal life. If you need to transfer oils or solvent-based fluids, compare alternative elastomer and wetted-material options specifically rated for those chemicals and confirm with manufacturer compatibility data.
A4: Start with required flow rate (how fast you need to fill) and duty cycle (occasional fills vs. frequent/continuous use). Then check viscosity at your operating temperature, suction lift needs (height from drum to pump), and discharge restrictions (hose length, nozzle, valves, or piping). Manufacturer performance curves or application notes are the most reliable way to confirm the pump meets your real-world setup.
A5: Verify the container type (drum vs. tote), bung thread size, and the depth needed for the suction tube to reach near the bottom without contacting it. Also confirm whether you need a specific adapter, stabilizer, or extension. Small fit mismatches are a common cause of wobble, leakage, or poor pickup near the end of the drum.
A6: They can be used for controlled dispensing, but repeatability depends on the exact configuration, fluid properties, and how the discharge is controlled (valve/nozzle/metering accessory). If you need consistent fill volumes, evaluate whether the pump supports add-on meters or a standardized dispensing valve, and confirm accuracy expectations under your operating conditions.
A7: Follow the manufacturer’s guidance for flushing and storage. In general, use cleaning/flush fluids that are compatible with EPDM and the pump’s other wetted materials, and avoid leaving incompatible chemicals sitting in the pump. If performance drops (slower prime, drips, or leakage), inspect check components and seals and verify whether an EPDM service kit is available for your exact model.
A8: Share the fluid name and SDS, concentration, temperature, and any known incompatibilities; your container type and bung size; desired flow rate; hose/nozzle or piping details; and whether the transfer is occasional or frequent. If safety requirements apply (static control, ventilation, or specific materials), include those constraints so the correct EPDM (200 Series) Goat Throat Pump configuration can be matched to your process.