Shop By Category
Help & Settings
- Customer Service
- Sign in / Sign up
Shop industrial LED stop & go corner light sets at Janeice Products Co Inc in Aiken, South Carolina. These dock-visibility light sets are used to clearly signal “stop” and “go” status at the corners of a dock position, helping drivers and dock teams coordinate trailer approach, backing, and departure. They’re a practical fit for busy shipping/receiving doors, shared-yard facilities, cold storage operations with limited sightlines, and any dock where pedestrians, forklifts, and trucks operate in close proximity. Use corner-mounted indication to improve line-of-sight from multiple approach angles and reduce confusion during trailer staging and loading workflows.
Sort By
Start by matching the light set to how your dock position is controlled. Some installations want the corner lights to mirror an existing dock communication system (for example, a control panel, dock lock, overhead door interlock, or vehicle restraint logic), while others prefer a simpler manual switch. Confirm the required input/control method (dry contact, relay output, or other control scheme), whether the set is intended to operate as a pair, and what your facility considers “stop” vs “go” states for inbound/outbound traffic. If you have multiple dock doors, plan for consistent logic and labeling across positions to avoid driver confusion.
Next, size the solution to the environment and viewing needs. Corner placement can improve visibility for angled approaches, but you still need to verify viewing distance, beam/spread, and whether the LEDs are bright enough for full sun or yard lighting conditions. Check mounting location constraints (corner clearance, wall material, and impact exposure), and choose housings and lenses appropriate to the dock’s moisture, dust, washdown, temperature swings, or corrosion potential. If forklifts or trailers can strike the units, look for protective design options and consider placement that reduces impact risk without sacrificing line-of-sight.
Finally, don’t overlook electrical and integration details that can slow an install. Confirm supply voltage, current draw, wiring entry orientation, conduit compatibility, and whether the set requires additional components (power supply, controller, junction box, surge protection). If you need the light state to be visible to both yard traffic and dock personnel, verify whether the corner light set supports the indication pattern you want (steady vs flashing, single-color vs dual-color, or separate red/green modules) and whether the manufacturer specifies acceptable flash rates and duty cycles for continuous operation. Always verify final wiring and interlocks against the manufacturer documentation and your site safety procedures.
A1: It provides a clear red/green (stop/go) visual signal at the corners of a dock position so drivers can see dock status from approach angles. It’s commonly used to indicate when a truck should hold, when backing is permitted, or when it’s safe to depart—based on your facility’s operating procedure and any interlocks you use.
A2: Corner placement can improve line-of-sight for drivers approaching at an angle, in multi-door rows, or where canopies, columns, or parked equipment block straight-on fixtures. Many sites use corner lights to reinforce a primary signal location so the status is visible earlier and from more angles.
A3: Check the manufacturer’s electrical specifications for the specific set: supply voltage, current draw, and wiring diagram. Also verify how it’s controlled (for example, contact closure vs a powered input), required conduit/cable entry, and whether any external power supply or controller is needed. If you’re retrofitting into an existing dock control circuit, confirm compatibility before installation.
A4: Often they can, but it depends on the restraint/controller outputs and the light set’s input requirements. Confirm whether your equipment provides a relay output or other signal that can drive the stop/go inputs, and validate the logic so the displayed state matches your safety sequence (for example, “green” only when restraint is properly engaged and the sequence allows departure).
A5: Compare specified viewing distance, viewing angle, and LED intensity characteristics, and consider ambient conditions such as direct sun, yard lighting at night, and glare from wet pavement. If your dock is exposed to strong daylight, prioritize models intended for high-ambient visibility and verify placement so the driver can see the indication early in the approach.
A6: Some are, but not all. Check the enclosure sealing and environmental ratings for the exact model you’re considering, along with lens and housing materials. For washdown or corrosive environments, confirm the manufacturer’s guidance on chemical exposure and cleaning methods rather than assuming suitability.
A7: Steady indications are simple and widely understood, while flashing can be used to emphasize a caution state or attract attention in busy yards. If you want flashing, verify the model supports it (or that your controller can provide it) and confirm any limits on flash rate or continuous operation per the manufacturer’s documentation.
A8: Share the number of dock positions, indoor/outdoor mounting locations, desired mounting height/location, available power/voltage, preferred control method (manual switch vs integration), and any environmental concerns (washdown, salt air, impact risk). If integrating with existing dock equipment, include the equipment model info and the type of output available so compatibility can be checked with the manufacturer specifications.