Shop By Category
Help & Settings
- Customer Service
- Sign in / Sign up
Shop dividers for conductive dividable grid container at Janeice Products Co Inc in Aiken, South Carolina. These divider sets are used to segment a conductive, grid-style container into smaller cells so you can separate components, prevent part-to-part contact, and keep pick/pack or kitting workflows organized without switching to multiple bins. They’re especially useful for electronics and electro-mechanical parts handling where controlling static charge is a concern, as well as for maintenance cribs, repair benches, and production lines that need fast visual access to sorted inventory. Choose divider configurations that match your container model and the parts you store—so compartments stay stable, accessible, and consistent across shifts and replenishment cycles.
Sort By
Start by matching the divider system to the exact conductive dividable grid container it’s intended for. Grid containers and their dividers are commonly designed as a paired system—cell pitch, divider height, tab/slot geometry, and wall thickness can vary by manufacturer and even by container size. Before ordering, verify the container’s part number (or interior dimensions and grid pattern) and confirm the divider set is specified to fit that model so the panels lock in correctly and don’t bow, pop out, or leave gaps that let small parts migrate between cells.
Next, choose a compartment layout that fits how the parts are used—not just how many SKUs you want in one box. For kitting and line-side replenishment, fewer, larger cells often speed picking and reduce mis-picks; for small passives, fasteners, or mixed hardware, higher cell counts can improve density and control. Consider whether parts will be removed by hand, with tweezers, or with a vacuum pick—access method affects ideal cell opening size and divider height. Also account for vibration and movement (cart transport, conveyors, tote dumping): tighter-fitting divider intersections and more rigid panels can help maintain the grid during handling.
A frequently overlooked check is static-control continuity across the divider assembly. “Conductive” properties can differ by resin, thickness, and surface condition, and some systems rely on contact between panels and container walls to maintain conductivity. If the application is ESD-sensitive, confirm the divider material and any specified resistance range per the manufacturer’s data, and consider cleaning practices—some cleaners and residues can affect surface performance. When ESD compliance is required, validate the complete container + divider configuration against your facility’s ESD program requirements rather than assuming any divider will be acceptable.
A1: Often they’re not. Divider thickness, slot spacing, and the grid pitch inside the container can vary by manufacturer and by container size. For best results, match the divider kit to the container’s specific model/part number or confirm fit using the manufacturer’s stated compatibility and interior grid dimensions.
A2: Base it on the parts’ footprint and how they’re picked. Use fewer/larger cells for bulky items or fast picking (connectors, relays, fittings) and more/smaller cells for high-mix small items (screws, terminals, passives). Also consider movement—if containers ride on carts or conveyors, layouts with tighter intersections and fewer ultra-small cells may better resist shifting and cross-migration.
A3: Not automatically. Conductive dividers can help maintain a conductive environment, but ESD suitability depends on the full system: the container material, divider material, contact between panels and container walls, and your facility’s ESD control program. If you need a specific resistance range or compliance target, verify the manufacturer’s electrical properties for the divider set and validate the complete assembled configuration in your process.
A4: For handling ESD-sensitive electronic components, conductive or static-dissipative materials are commonly specified depending on your grounding and packaging requirements. Conductive materials generally provide lower resistance, while dissipative materials slow discharge. Your ESD program (and component sensitivity) should drive the selection; confirm the manufacturer’s published resistance range and intended ESD use rather than choosing by color or appearance.
A5: Stability depends on the divider locking design, panel rigidity, and how tightly the kit fits the container’s grid. If bins move frequently, prioritize divider sets with positive engagement (tabs/slots that lock firmly) and sufficient stiffness to prevent bowing. Also consider whether a compatible cover or retention method is needed for your workflow—verify with the container’s accessory options.
A6: Some divider styles can be trimmed, but doing so may weaken intersections, reduce retention, or alter conductive performance. If customization is necessary, check the manufacturer’s guidance first and consider ordering alternate divider configurations designed for your container. For ESD-critical applications, validate that any modification doesn’t compromise electrical properties or cleanliness requirements.
A7: Use cleaning methods recommended by the divider/container manufacturer. In general, avoid harsh solvents or waxy cleaners that can leave insulating residues or degrade plastic. If ESD control is important, ensure cleaning and drying practices align with your ESD program and verify surface condition periodically, since contamination and residues can change electrical behavior.
A8: Share the conductive dividable grid container’s manufacturer and model/part number, the container size, and the compartment layout you want (number of rows/columns or cell count). If the application is ESD-sensitive, also specify any resistance-range requirements and whether you use lids/covers or stacking so compatibility can be confirmed before you place the order.